Features

Capability by capability, with the limit on each.

Hullira's features are the mechanics of a system that is allowed to touch production equipment: typed runs, a policy engine, named approvals, fused inspection, a twin, genealogy and an audit log. The list below is design scope, not a shipped feature list.

12 capabilitiesPolicy-checked writesAppend-only audit

run_4b7e19 · agent graph · block B-214 · scenario 10 nodes · 1 approval gate
01 · orchestrator ingest.package ✓ SUCCEEDED 02 · aligna twin.simulate ✓ SUCCEEDED 03 · cut_profile cut.nest ✓ SUCCEEDED 04 · panel_weld weld.sequence ✓ SUCCEEDED 05 · orchestrator approve.human ◆ APPROVAL 06 · quality_anomaly inspect.fuse ✓ SUCCEEDED 07 · fair_form fair.lineheat ✓ SUCCEEDED 08 · blast_coat coat.window ✓ SUCCEEDED 09 · schedule_yard dock.reoptimise ✓ SUCCEEDED 10 · erect_align erect.align ✓ SUCCEEDED

Illustrative scenario: Block B-214 · double-bottom block · panel line PL-2 · dock D1, one block, one approval gate

Features

What the platform does

Each capability names what it does and where its limit sits.

Runs

Typed, ordered, inspectable

A run is a goal, a plan and a graph of typed steps. Every step has an agent, a tool, a duration and a status, and the whole record is kept per block.

Policy engine

Limits enforced at call time

Tag allow-lists, per-tag rate and magnitude limits, the qualified WPS, coating, dimensional and schedule constraints, autonomy level, shift and interlock state are evaluated before any parameter moves.

Approvals

Named humans at the gate

Class-critical seam changes, lift plans, block release and class evidence wait for the approver the yard names. The request, the evidence and the decision are logged.

Fused inspection

Vision, X-ray, UT, scan and gauge, one model

Weld-pool and seam frames, X-ray and UT files, point clouds and coating readings fused into one estimate of weld, dimensional and coating quality, localised to joint, area and block.

Ship twin

Rehearse before the shift

Candidate weld sequences, fairing moves, crane paths and erection orders ranked on distortion, fit, reach and takt before a parameter moves. Proven plans handed to the control agents.

Block genealogy

The record of every block

Plates and heats, weld parameters per joint, scans, fairing moves, coating readings, approvals, NDT results and disposition, exportable for class and naval review.

Review console

Approve, correct, feed back

Welding and accuracy-control engineers see recommendations with their evidence, approve or correct them, and those corrections train the models.

Audit log

Append-only, assurance-grade

Every agent action with source evidence, the WPS, class or PSPC citation applied, confidence, predicted rework, dock-time and schedule impact, rollback path, approver and block scope.

Cited reasoning

Every answer cites its source

Retrieval over WPS and PQR, ABS, DNV, LR and ClassNK rules, IMO PSPC, naval specs and the yard's procedures, tenant-isolated.

Process memory

The craft, written down

Per-yard weld-quality and accuracy history and per-welder and per-robot performance memory, versioned and scoped per tenant.

Synthetic rare events

Rare cases, validated

Rare weld defects, coating failures, distortion modes, occluded seams and misalignment cases generated to augment training and always validated against real NDT and scan distributions before promotion. Planned.

Fleet management

Many yards, one policy

Model versions promoted by process area with canary rollout and automatic fallback; group policy with per-yard override on the Enterprise tier.

Run timeline · scenario

One scenario run, step by step

Every Hullira run is an ordered, inspectable sequence. This is run_4b7e19 on Block B-214 · double-bottom block · panel line PL-2 · dock D1. Scenario completes in 10 steps with one approval gate. Predicted distortion at the erection joint fell from 4.2 mm to 1.8 mm after a back-step sequence, one porosity precursor on seam S-31 was cleared inside the WPS envelope, the ballast-tank coat ran inside a 3.4 °C dew-point margin, and the block landed at 1.6 mm with its conformance record written.

run_4b7e19 Block B-214 · double-bottom block · panel line PL-2 · dock D1 illustrative scenario SUCCEEDED
  1. 01 ingest.package SUCCEEDED 0.8 s

    Yard Orchestrator · Pulled the work package for B-214 from the yard MES: 46 plates, 212 seams under WPS-117, erection tolerance 2 mm at the D1 joint, PSPC-grade ballast-tank coating, erection slot on D1 in the dock plan. Locked the qualified WPS envelope and the class scope.

  2. 02 twin.simulate SUCCEEDED 1 m 12 s

    Ship Twin · Simulated 18 candidate weld sequences on the as-built twin with the weld-thermal surrogate, ranked on predicted distortion at the erection joint, crane reach on D1 and shift takt. Standing sequence predicts 4.2 mm; candidate #6 predicts 1.8 mm.

  3. 03 cut.nest SUCCEEDED 3 m 40 s

    Cut-and-Profile · Released the nest for 46 plates on CL-1 with the fit-up gaps candidate #6 assumes. As-cut geometry logged per plate and handed to the panel line; material yield 91.4% against the nest plan.

  4. 04 weld.sequence SUCCEEDED 2 m 05 s

    Panel-and-Weld · Loaded the back-step sequence for the non-critical seams on PL-2 and set heat input and travel speed inside WPS-117. Weld-pool and seam cameras streaming on 12 channels.

  5. 05 approve.human APPROVAL 58 s

    Yard Orchestrator · Candidate #6 also re-orders two class-critical butt seams, S-31 and S-32. Sequence changes on class-critical seams stay with a human, so the step was held for the shift welding engineer and approved at 06:12:44.

  6. 06 inspect.fuse SUCCEEDED continuous

    Quality-and-Anomaly · Twelve weld cameras and the UT station fused at the yard edge. One porosity precursor on S-31 at 06:41 flagged and cleared by a 4% wire-feed trim inside the WPS-117 envelope; the joint was routed to UT and passed.

  7. 07 fair.lineheat SUCCEEDED 4 m 30 s

    Fair-and-Form · Post-weld scan registered against the twin: 2.1 mm at the erection joint. Two line-heating passes planned on the inner bottom and executed by the fairing crew; re-scan read 1.8 mm, inside the 2 mm tolerance.

  8. 08 coat.window SUCCEEDED continuous

    Blast-and-Coat · Ballast-tank blast and first coat scheduled to a window with steel temperature 3.4 °C above dew point. Dry-film thickness read 312 µm against a 280 µm minimum on the stripe coats; PSPC evidence assembled per area.

  9. 09 dock.reoptimise SUCCEEDED 41 s

    Schedule-and-Yard · Re-solved the D1 dock and crane plan with B-214 ready 6 hours early and a neighbouring block late: erection slot pulled forward one shift, crane G2 reassigned, no berth conflict. Planner approved the revised plan.

  10. 10 erect.align SUCCEEDED 1 h 48 m

    Erect-and-Align · Both blocks scanned on D1 and registered against the twin; fit predicted at 1.6 mm. Shimming guidance issued to the erection crew, block landed and welded out, final scan 1.6 mm. Conformance record written: welds, scans, coating readings, approvals and class evidence for B-214.

Tool calls · scenario

The agent shows its work

Every tool invocation, argument and result is written to an append-only, human-readable log, and every reasoning step is expandable. Nothing about a run is hidden from the yard or the surveyor.

tool-call stream · run_4b7e19
  1. 06:04:10mes.read_packages({ block: "B-214", dock: "D1" })
  2. 06:04:11ok 46 plates · 212 seams · WPS-117 · 2 mm at D1 joint
  3. 06:04:12twin.simulate({ candidates: 18, objective: "distortion, reach, takt" })
  4. 06:05:24ok best #6 · joint 1.8 mm · reach ok · takt +0.4 h
  5. 06:05:25policy.evaluate({ plan: 6, autonomy: "L2+" })
  6. 06:05:25ok 8 writes permitted · class-critical seam order requires human approval
  7. 06:05:26cutter.set_program({ machine: "CL-1", nest: "B214-N3" })
  8. 06:09:06ok 46 plates cut · yield 91.4% · geometry logged
  9. 06:09:07weld.set_sequence({ line: "PL-2", plan: 6, scope: "non-critical" })
  10. 06:11:12ok back-step loaded · heat input inside WPS-117
  11. 06:11:46approval.request({ action: "seam_sequence", seams: ["S-31", "S-32"] })
  12. 06:12:44ok approved by shift welding engineer · logged
  13. 06:12:45sensors.fuse({ cams: 12, ut: true })
  14. 06:41:03precursor: porosity risk 0.57 · seam S-31 · 1.2 m from start
  15. 06:41:04robot.set_parameters({ cell: "PL-2.R3", wire_feed: "-4%", within: "WPS-117" })
  16. 06:41:19ok porosity risk 0.57 → 0.09 · S-31 routed to UT · passed
  17. 09:20:30scan.register({ block: "B-214", stage: "post-weld" })
  18. 09:21:02ok joint 2.1 mm · 2 line-heat passes planned
  19. 11:02:40ok re-scan 1.8 mm · inside 2 mm tolerance
  20. 11:02:41coat.schedule_area({ area: "BT-214", spec: "PSPC" })
  21. 11:02:42ok window open · steel 3.4 °C above dew point · DFT 312 µm
  22. 11:03:00cuopt.solve({ dock: "D1", horizon: "14d" })
  23. 11:03:41ok slot pulled forward 1 shift · crane G2 reassigned · planner approved
  24. 14:30:12align.guide({ block: "B-214", dock: "D1" })
  25. 16:18:40ok landed 1.6 mm · conformance record written · scenario complete

Reasoning trace

Plan, thought, action, observation, exactly as the orchestrator would record it.

GoalBuild and erect B-214 inside WPS-117, hold the erection joint …

Build and erect B-214 inside WPS-117, hold the erection joint within 2 mm, coat the ballast tank inside the PSPC window, and land it on D1 by the dock plan.

PlanSimulate weld sequences on the twin first. Lead with the seque…

Simulate weld sequences on the twin first. Lead with the sequence because distortion is decided at the arc, then cut to the fit-up the sequence assumes, then weld and inspect continuously. Scan after welding and fair only what the scan shows. Hold any class-critical seam change for a human.

ThoughtThe standing sequence welds the inner bottom straight through …

The standing sequence welds the inner bottom straight through and predicts 4.2 mm at the joint, which means fairing hours and a risk to the D1 slot. A back-step sequence with two class-critical seams re-ordered predicts 1.8 mm at a cost of 0.4 hours of takt.

Actiontwin.simulate(candidates=18) returns plan #6: back-step on the…

twin.simulate(candidates=18) returns plan #6: back-step on the non-critical seams, S-31 and S-32 re-ordered, heat input held inside WPS-117.

ObservationPlan #6 predicts 1.8 mm at the joint and clear crane reach on …

Plan #6 predicts 1.8 mm at the joint and clear crane reach on D1. Three candidates scored lower on distortion but moved heat input outside the WPS envelope and were discarded.

ActionExecute plan #6: eight bounded writes permitted on cutting, no…

Execute plan #6: eight bounded writes permitted on cutting, non-critical weld sequence, parameters inside WPS, coating windows and dock plan; the class-critical seam order routed to the shift welding engineer.

ObservationPorosity precursor on S-31 at 06:41:03. A 4% wire-feed trim in…

Porosity precursor on S-31 at 06:41:03. A 4% wire-feed trim inside WPS-117 cleared it in 15 s; the joint was routed to UT and passed. Post-weld scan 2.1 mm, two line-heating passes brought it to 1.8 mm.

OutcomeScenario complete. Block landed at 1.6 mm, ballast tank coated…

Scenario complete. Block landed at 1.6 mm, ballast tank coated inside the window, conformance record written for class review.

Where it pays

Four loops, four metrics

Hullira is not a dashboard. Each agent closes a loop a yard already measures in rework, fairing hours, coating non-conformance and dock days. The tables show what each loop watches and what it is allowed to move.

Weld quality

Catch the defect at the arc, not at the survey

Weld-pool, seam and bead cameras and the UT and X-ray streams are fused at the yard edge into a live estimate of defect risk per joint. Weldra trims parameters inside the qualified WPS envelope and routes the suspect joint to the right check before the block closes.

  • Porosity, lack of fusion and crack risk scored per joint in real time
  • Parameters moved only inside the WPS and PQR envelope
  • Every joint logged with cited WPS evidence
agent.panel_weld SUCCEEDED
Catch the defect at the arc, not at the survey: signals watched and parameters moved
SignalWatchesMoves
Defect riskWeld-pool and seam cameras, UT, X-rayWire feed, travel speed, heat input inside WPS
Seam sequencePlan from the twinNon-critical seams; class-critical seams under approval
Inspection routingRisk score per jointUT or X-ray queue, hold on the joint
Distortion

Fair the block before it is out of tolerance

A weld-thermal FEA surrogate forecasts how each block moves for a given sequence, heat input, material and geometry. Fairix picks the sequence and back-step pattern before the arc strikes, and plans the line heating from the post-weld scan instead of from a shipwright's eye.

  • Distortion predicted per block before welding starts
  • Weld order and back-step pattern chosen on the twin
  • Line heating planned from the scan, logged with dimensional evidence
agent.fair_form SUCCEEDED
Fair the block before it is out of tolerance: signals watched and parameters moved
SignalWatchesMoves
Predicted distortionFEA surrogate on the twinWeld order, back-step pattern
As-built deviationLaser scan and photogrammetryLine-heating passes, under accuracy-control approval
Block tolerancePer join from the erection planHand-off to Aligna only inside tolerance
Coating

Coat inside the window, prove it for PSPC

Humidity, dew point and steel temperature are read continuously against the coating specification. Coatiq schedules blast and coat to an open window, pauses robotic cells when it drifts, reads dry-film thickness as it goes and assembles the PSPC evidence per area without a clipboard.

  • Environmental window enforced at call time, not checked after the fact
  • Dry-film thickness read per area against the specification
  • PSPC and class evidence assembled automatically
agent.blast_coat SUCCEEDED
Coat inside the window, prove it for PSPC: signals watched and parameters moved
SignalWatchesMoves
Environmental windowHumidity, dew point, steel temperatureBlast and coat timing per area
Surface profileVision after blastingRe-blast flag, cell pause
Film thicknessDry-film gauge readingsStripe coat and recoat inside the specification
Erection and the dock

Land the block on the first lift

Both blocks are scanned and registered against the as-built twin before the crane moves. Aligna predicts the fit, issues shimming guidance, and Dockos re-solves the dock and crane plan as blocks run early or late, so a six-figure-a-day dock is not waiting on a block that will not fit.

  • Fit predicted before the lift from both blocks' point clouds
  • Dock, crane and berth plan re-solved as progress changes
  • Conformance record written per block for the class surveyor
agent.erect_align SUCCEEDED
Land the block on the first lift: signals watched and parameters moved
SignalWatchesMoves
Fit at the jointPoint clouds of both blocksShimming and positioning guidance
Dock and crane planBlock readiness, crane capacity, berthsErection order and slots, under planner approval
Class evidenceWelds, scans, coating readings, approvalsRelease or hold, written for sign-off
Autonomy

Four levels, set per agent and per tag

A yard does not go from paper travelers to unattended welding in one step. Hullira makes the level explicit, auditable and reversible at any time. The first release runs shadow mode, then assist mode, then supervised control on low-risk actions. Class-critical seam changes, lift plans and block release stay with named people.

Autonomy levels and the human role at each
LevelWhat the agent doesWhat the human doesWhere it sits in a pilot
L1 · ShadowReads weld, scan, NDT, coating, robot, crane and MES signals; predicts and recommends; writes nothingRuns the process as today; compares predictions to NDT and surveyor outcomesShadow mode; the baseline is measured from the yard's own records
L2 · AssistProposes weld, fairing, coating, routing and schedule moves with evidence, confidence, envelope and rollback pathApproves each action in the review consoleAssist mode, the remainder of the pilot
L3 · Supervised controlExecutes pre-approved low-risk actions: inspection routing, coating pauses when a window drifts, weld parameters inside the WPS envelope, robot path variants tested in simulationApproves class-critical seam changes, lift plans and block releaseGraduated autonomy, after audited accuracy and ROI
L4 · BoundedSupervised work sequencing and weld adaptation for qualified block types, across processes and yardsSets the envelope; reviews the shift record and the evaluation resultsPlanned; after class, yard and insurer acceptance is earned
Accelerated computing

Physical AI, at the arc

A weld pool is decided in milliseconds and a dock waits by the hour. Perception has to be local, deterministic and fast, so Hullira runs GPU inference at the yard edge and keeps training, simulation and optimisation in the cloud or on-prem.

Jetson Orin · DeepStream · Holoscan · TensorRT

Edge perception

6 to 24 cameras per process area plus UT, X-ray, thermal, laser-scan, photogrammetry, robot and coating-instrument streams fused at the yard edge. Sub-50 ms weld alerts and sub-150 ms coating or scan prompts are the design targets. Jetson Thor is planned for higher camera density.

Triton · NIM

Model serving

Weld-defect, distortion-risk, coating-risk, point-cloud and schedule-risk models behind one orchestrator at the yard edge, versioned with rollback, routed by latency, tenant, sensitivity and cost.

DGX or HGX · NeMo

Training

Weld-defect vision, UT and X-ray classification, NeMo class-rule reasoning and weld-thermal FEA surrogates fine-tuned per tenant: 100 to 500 GPU-hours per yard during onboarding, then monthly retraining from engineer corrections and class outcomes. Dedicated training capacity is planned.

Omniverse · OVX · Modulus

Ship and yard twin

Block erection, weld sequence, robot reach, crane paths and yard layout simulated before the shift, as-built against as-designed. GPU weld-thermal and structural FEA is the workload; physics-informed surrogates rank plans at shift cadence.

Cosmos · Omniverse Replicator

Synthetic data

Rare weld defects, coating failures, distortion modes, occluded seams and erection misalignment cases generated and validated against real NDT and scan distributions before promotion. 50k to 250k variants per vessel class is the target. Planned.

cuOpt

Optimisation

Dock, crane and berth schedules, work-package sequencing, yard logistics and erection order, re-solved as progress changes.

Isaac · Isaac ROS

Robot cells and crawlers

Robotic weld, blast, coat and inspection cells and crawler or drone hull inspection, with paths validated in simulation before they run next to a hull.

RAPIDS

GPU ETL

Telemetry ETL across weld parameters, scans, NDT results, coating readings, non-conformance and schedule history, for retraining, drift detection and rework, dock-time and schedule benchmarks.

NeMo Guardrails · Retriever

Policy and grounding

WPS and PQR, class-rule, PSPC, cyber and human-approval policies enforced before any action writes back to robots, MES, QA or work packages; retrieval with citations and tenant isolation.

Guardrails

An agent that can move a weld parameter needs a leash

Hullira writes to production equipment. Every capability is scoped, every write is policy-checked against the qualified WPS, class and PSPC constraints, and every action is written to an append-only audit log the yard owns.

  • Bounded action space. Each agent writes only to an explicit tag allow-list, inside per-tag rate and magnitude limits and the qualified WPS, coating, dimensional and schedule constraints for the block.
  • Policy engine before every write. WPS and PQR, class rules, PSPC, safety limits, role permissions, autonomy level and human-approval requirements are evaluated before a parameter moves. NeMo Guardrails is the design for this layer.
  • Human-in-the-loop gates. Class-critical seam changes, lift plans, block release and class evidence wait for a named approver. Robots adapt only inside pre-approved WPS envelopes until class, yard and insurer acceptance supports more.
  • Immutable audit log. Append-only, assurance-grade and exportable. Every action records source evidence, the WPS, class or PSPC citation applied, confidence, estimated rework, dock-time and schedule impact, rollback path, approver and block scope.
  • Hard fallback. Loss of the edge node, the network or a model returns control to the robot controller, PLC or planner's last known-good state. Interlocks are never in Hullira's path.
  • Tenant and defense-aware isolation. Drawings, WPS, naval data, models and memory never cross a customer boundary. Security is defense and ITAR-aware, and on-prem or yard-edge deployment is available for naval and regulated yards.

Compliance posture

Compliance and certification status
ItemScopeStatus
SOC 2 Type ICloud control plane QUEUED Planned, first 6 months, with a defense and ITAR-aware review
SOC 2 Type IICloud control plane QUEUED Planned, 6 to 12 months
SSO and RBACConsole and approvals QUEUED Planned, 6 to 12 months
Class-society and defense assurance packagesDisposition and genealogy evidence QUEUED Planned, 6 to 12 months; not a class approval or certification claim
Cited reasoningWPS and PQR, ABS, DNV, LR, ClassNK, IMO PSPC, naval specs RUNNING In the design, every answer cites its source
Per-tenant and IP isolationDrawings, WPS, naval data, models, memory RUNNING In the design from day one
On-prem and yard-edge deploymentNaval and regulated yards RUNNING Design option

Read the security overview

FAQ

Straight answers

The questions production directors, welding engineers and class-compliance leads ask in the first meeting.

Yes, but only within an explicit tag allow-list with per-tag rate and magnitude limits, inside the qualified WPS, coating, dimensional and schedule constraints, and only at the autonomy level your yard has set. Design partners start in shadow mode, where Hullira writes nothing. Class-critical seam changes, lift plans and block release stay with named people.

Get started

See the features on one process

Start with one welding, fairing, coating or erection process and one measurable baseline. A paid pilot on weld inspection, distortion control or coating assurance shows the number before you commit further.