Contact

Start with the process that is costing you the most.

Hullira starts with a paid pilot on one welding, fairing, coating or erection process and a baseline agreed in writing. Tell us the process, the metric and the systems on it. We will say plainly whether the wedge fits and what the pilot would look like.

hello@hullira.comPaid pilot · one processReply from the founding team

Tell us about your process

This form opens your mail client addressed to hello@hullira.com. Nothing is stored on this site.

Reasons

Why people get in touch

Pilot

Run a wedge on one process

Weld inspection, distortion control or coating assurance, with a metric you already measure.

Partner

Ship Hullira-ready

Welding-robot, CAD/CAM, scan, NDT and coating OEMs, class societies, MES vendors, integrators.

Security

Send the questionnaire

We answer plainly, including what is planned rather than done, and where defense controls apply.

Careers

Found something

Edge perception, OT integration, simulation, welding or accuracy-control engineering.

Press and research

Ask a question

On dock economics, weld quality, distortion, the twin and autonomy in the yard.

Investors

Pre-seed conversation

Pre-revenue, pre-institutional. We do not claim traction we do not have.

The pilot

What an engagement looks like

The first-release plan, applied to your process. We publish no pilot length because we have not run one yet.

  1. Connect and observe. Read-only connection to the wedge process, the time-aligned block record built, the baseline measured from your own NDT, scan, coating and schedule records.
  2. Then assist. Recommendations with evidence in the review console; your engineer approves each one; accuracy and ROI measured against the signed baseline.
  3. Supervised control, if you are satisfied. Pre-approved low-risk actions run inside declared limits; class-critical seams, lift plans and block release stay with named humans.
  4. Decision. Convert to the Process tier and expand, or stop with the record of what was measured.
Run timeline · scenario

What we would be deploying

Every Hullira run is an ordered, inspectable sequence. This is run_4b7e19 on Block B-214 · double-bottom block · panel line PL-2 · dock D1. Scenario completes in 10 steps with one approval gate. Predicted distortion at the erection joint fell from 4.2 mm to 1.8 mm after a back-step sequence, one porosity precursor on seam S-31 was cleared inside the WPS envelope, the ballast-tank coat ran inside a 3.4 °C dew-point margin, and the block landed at 1.6 mm with its conformance record written.

run_4b7e19 Block B-214 · double-bottom block · panel line PL-2 · dock D1 illustrative scenario SUCCEEDED
  1. 01 ingest.package SUCCEEDED 0.8 s

    Yard Orchestrator · Pulled the work package for B-214 from the yard MES: 46 plates, 212 seams under WPS-117, erection tolerance 2 mm at the D1 joint, PSPC-grade ballast-tank coating, erection slot on D1 in the dock plan. Locked the qualified WPS envelope and the class scope.

  2. 02 twin.simulate SUCCEEDED 1 m 12 s

    Ship Twin · Simulated 18 candidate weld sequences on the as-built twin with the weld-thermal surrogate, ranked on predicted distortion at the erection joint, crane reach on D1 and shift takt. Standing sequence predicts 4.2 mm; candidate #6 predicts 1.8 mm.

  3. 03 cut.nest SUCCEEDED 3 m 40 s

    Cut-and-Profile · Released the nest for 46 plates on CL-1 with the fit-up gaps candidate #6 assumes. As-cut geometry logged per plate and handed to the panel line; material yield 91.4% against the nest plan.

  4. 04 weld.sequence SUCCEEDED 2 m 05 s

    Panel-and-Weld · Loaded the back-step sequence for the non-critical seams on PL-2 and set heat input and travel speed inside WPS-117. Weld-pool and seam cameras streaming on 12 channels.

  5. 05 approve.human APPROVAL 58 s

    Yard Orchestrator · Candidate #6 also re-orders two class-critical butt seams, S-31 and S-32. Sequence changes on class-critical seams stay with a human, so the step was held for the shift welding engineer and approved at 06:12:44.

  6. 06 inspect.fuse SUCCEEDED continuous

    Quality-and-Anomaly · Twelve weld cameras and the UT station fused at the yard edge. One porosity precursor on S-31 at 06:41 flagged and cleared by a 4% wire-feed trim inside the WPS-117 envelope; the joint was routed to UT and passed.

  7. 07 fair.lineheat SUCCEEDED 4 m 30 s

    Fair-and-Form · Post-weld scan registered against the twin: 2.1 mm at the erection joint. Two line-heating passes planned on the inner bottom and executed by the fairing crew; re-scan read 1.8 mm, inside the 2 mm tolerance.

  8. 08 coat.window SUCCEEDED continuous

    Blast-and-Coat · Ballast-tank blast and first coat scheduled to a window with steel temperature 3.4 °C above dew point. Dry-film thickness read 312 µm against a 280 µm minimum on the stripe coats; PSPC evidence assembled per area.

  9. 09 dock.reoptimise SUCCEEDED 41 s

    Schedule-and-Yard · Re-solved the D1 dock and crane plan with B-214 ready 6 hours early and a neighbouring block late: erection slot pulled forward one shift, crane G2 reassigned, no berth conflict. Planner approved the revised plan.

  10. 10 erect.align SUCCEEDED 1 h 48 m

    Erect-and-Align · Both blocks scanned on D1 and registered against the twin; fit predicted at 1.6 mm. Shimming guidance issued to the erection crew, block landed and welded out, final scan 1.6 mm. Conformance record written: welds, scans, coating readings, approvals and class evidence for B-214.

Pricing

Priced per process, per yard, per group

Land on one workflow with a measured baseline. Expand by process, yard, group site and autonomy level. Outcome components are available on rework, dock time and schedule value. Annual prepay carries a 15 to 20% discount.

Process $12,000 per production process or area / month · billed monthly

Weld, fairing or coating control, or weld-inspection AI, for one process. For yards validating ROI on the wedge.

  • One process or area, one agent module
  • Yard-edge inference node included
  • Robot, instrument and MES reads, guarded writes
  • Run log, audit trail, block genealogy
  • Business-hours support
Start a pilot
Enterprise Custom land $700k to $10M ACV

Multi-yard groups and naval programs standardising on Hullira, with custom weld, distortion and schedule models.

  • Multi-yard and program fleet management
  • Custom weld, distortion and schedule models
  • Yard-edge fleet with on-prem option
  • Group autonomy policy and approval chains
  • SLAs, SSO and RBAC, dedicated engineer
Contact us
Guardrails

An agent that can move a weld parameter needs a leash

Hullira writes to production equipment. Every capability is scoped, every write is policy-checked against the qualified WPS, class and PSPC constraints, and every action is written to an append-only audit log the yard owns.

  • Bounded action space. Each agent writes only to an explicit tag allow-list, inside per-tag rate and magnitude limits and the qualified WPS, coating, dimensional and schedule constraints for the block.
  • Policy engine before every write. WPS and PQR, class rules, PSPC, safety limits, role permissions, autonomy level and human-approval requirements are evaluated before a parameter moves. NeMo Guardrails is the design for this layer.
  • Human-in-the-loop gates. Class-critical seam changes, lift plans, block release and class evidence wait for a named approver. Robots adapt only inside pre-approved WPS envelopes until class, yard and insurer acceptance supports more.
  • Immutable audit log. Append-only, assurance-grade and exportable. Every action records source evidence, the WPS, class or PSPC citation applied, confidence, estimated rework, dock-time and schedule impact, rollback path, approver and block scope.
  • Hard fallback. Loss of the edge node, the network or a model returns control to the robot controller, PLC or planner's last known-good state. Interlocks are never in Hullira's path.
  • Tenant and defense-aware isolation. Drawings, WPS, naval data, models and memory never cross a customer boundary. Security is defense and ITAR-aware, and on-prem or yard-edge deployment is available for naval and regulated yards.

Compliance posture

Compliance and certification status
ItemScopeStatus
SOC 2 Type ICloud control plane QUEUED Planned, first 6 months, with a defense and ITAR-aware review
SOC 2 Type IICloud control plane QUEUED Planned, 6 to 12 months
SSO and RBACConsole and approvals QUEUED Planned, 6 to 12 months
Class-society and defense assurance packagesDisposition and genealogy evidence QUEUED Planned, 6 to 12 months; not a class approval or certification claim
Cited reasoningWPS and PQR, ABS, DNV, LR, ClassNK, IMO PSPC, naval specs RUNNING In the design, every answer cites its source
Per-tenant and IP isolationDrawings, WPS, naval data, models, memory RUNNING In the design from day one
On-prem and yard-edge deploymentNaval and regulated yards RUNNING Design option

Read the security overview

Integrations

It speaks yard, not cloud

Hullira reads and writes through the systems already on the floor. No rip and replace, no parallel historian, no new HMI to learn. Vendor names are examples of systems found in yards, not certified integrations; connector availability is confirmed per site.

CAD/CAM and nesting

Shipyard CAD/CAM and production planning (Siemens NX Shipbuilding, Dassault CATIA and 3DEXPERIENCE, AVEVA Marine, SSI ShipConstructor, NAPA class systems)

Nests, drawings, as-designed geometry; guarded cut-program writes

Welding robots and power sources

Welding robots and weld-parameter controllers (Pemamek, Kranendonk, IMG, Fronius, Lincoln Electric, Panasonic class systems)

Parameter and sequence reads; writes inside the WPS envelope

Laser scan and photogrammetry

Dimensional and accuracy-control systems (Hexagon, FARO, BuildIT class tools)

Point clouds per block and stage; as-built registration

NDT

X-ray and UT stations and service houses (Waygate, Evident class systems)

Scans and indications per joint; routing and holds

Coating instruments and cells

Environmental sensors, dry-film gauges, robotic blast and spray systems

Humidity, dew point, steel temperature, thickness; cell pause and resume

Cranes, docks and transporters

Crane telemetry, dock and berth plans, block transporters

Capacity and position reads; plans under planner approval

Yard MES and scheduling

Yard MES, scheduling and twin systems (Siemens, Dassault, AVEVA, iBASEt, Aras, in-house systems)

Work packages, block genealogy, disposition write-back

Class and procedure documents

WPS and PQR, ABS, DNV, LR and ClassNK rules, IMO PSPC, naval quality specs

Tenant-isolated retrieval with citations

See all integrations

FAQ

Straight answers

The questions production directors, welding engineers and class-compliance leads ask in the first meeting.

Yes, but only within an explicit tag allow-list with per-tag rate and magnitude limits, inside the qualified WPS, coating, dimensional and schedule constraints, and only at the autonomy level your yard has set. Design partners start in shadow mode, where Hullira writes nothing. Class-critical seam changes, lift plans and block release stay with named people.

Get started

Or just send the numbers

Weld rework per block, fairing hours, coating non-conformance, dock days. We will tell you which wedge fits.